Two-Wire, Time of Day Secondary-Master Clock that Starts at 12:00 for School Districts

DC-Digital, Time of day, Secondary, Two-wired, White table, DC-25-1200-24,12:00-Rauland-2-Wire-System, Digital Clock, 2.3 Inch Digits, 24 VAC, school district secondary clocks,12-hour clocks for local school districts, secondary time of day clocks for master clocks, School Time Synchronization, Classroom Time Display, Master Clock System, Synchronized School Clock System, Secondary Time Clock, Custom Built to Order Clock
Clocks

South Kitsap School District has reached out to DC-Digital for their standard, secondary clocks to connect to their own master clock. The DC-25-1200-24 Secondary Time of Day Clock is designed to provide a clear, reliable 12-hour time display when synchronized with a master clock system. This standard secondary clock operates by directly tying into the same power source as the master clock, using shared neutral (white) and hot (black) wiring. By doing so, it ensures accurate time alignment while maintaining a simple and dependable installation method for industrial, commercial, and facility-wide timing applications.

This model follows a unique and intentional 12-hour reset cycle. After twelve hours of continuous operation, the internal power is briefly interrupted, causing the display to reset and return to 12:00. This reset occurs automatically and lasts only a few seconds before the unit resumes normal operation. The cycle repeats every twelve hours, ensuring the clock consistently maintains its intended 12-hour format without drifting or requiring manual adjustment.

In practical use, when the display approaches 12:00, the power interruption simulates a brief shutdown. Once power is restored, the display immediately resets to 12:00 and continues counting forward. This behavior is inherent to the design and is controlled entirely through its connection to the master clock’s wiring, eliminating the need for additional programming or user interaction.

From a hardware standpoint, the DC-25-1200-24 is built for durability and visibility. The enclosure is constructed from black powder-coated, 14-gauge aluminum, providing strong protection in demanding environments while maintaining a clean, professional appearance. The enclosure measures 9 inches wide, 4 inches tall, and 3 inches deep, making it compact enough for flexible mounting while still allowing ample internal space for wiring.

The display features four large digits, each measuring 2.3 inches in height. These digits are designed for long-distance visibility and can be clearly read from up to 120 feet away. The clock displays time of day exclusively in a 12-hour format, making it ideal for facilities that rely on traditional time representation.

Key features and specifications include:

  • Automatic 12-hour reset cycle with brief power interruption
  • Synchronization through direct connection to a master clock’s neutral and hot wiring
  • Four-digit, 12-hour time of day display
  • 2.3-inch digit height for high visibility up to 120 feet
  • 24 VAC low-voltage power operation
  • Black powder-coated, 14-gauge aluminum enclosure
  • Compact enclosure size of 9″ wide x 4″ tall x 3″ deep

For installation, the rear of the enclosure includes slotted teardrop knockouts compatible with standard 4×4 or 2×4 electrical rough-in boxes. This allows for secure wall mounting while simplifying alignment and installation in existing electrical infrastructure.

Overall, the DC-25-1200-24 Secondary Time of Day Clock provides a straightforward, dependable solution for synchronized time display, combining durable construction, high visibility, and a consistent 12-hour reset operation that integrates seamlessly with master clock systems.

See our tutorial video on model

See Standard Product: DC-25-1200-24

See DC-Digital Store

Contact us to ask about our customized products!

No Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

Board Replacement, LED Display Repair, Display Troubleshooting, Industrial Clock Repair, GPS Display Wiring, Clock Display Electronics, Display Maintenance, Surge Protection Wiring
Clocks
DC-Digital Display Maintenance Guide for DB2 Board Removal & Installation for Manufacturing Users

One of the advantages of DC-Digital display systems is their serviceability. In the unlikely event that a control board requires replacement, customers can often perform the repair themselves with basic hand tools and careful attention to wiring connections. This helps minimize downtime and allows critical clock, temperature, and information displays …

12 volt atomic GPS Vehicle clock automatic Daylight savings 2.3 inch LEDs, Special Vehicle Atomic Clock,bulk head clock,bulkhead clock,mobile vehicle center clock,Atomic Clock,Vehicle Clock,GPS Time Display,Multi Time Zone Clock,Vehicle Dashboard Clock,Transportation Time Display,Panel Mount Clock,Fleet Time Synchronization,Custom Built to Order Clock
Clean Room Clocks
Vehicle GPS- Atomic Clock

The DC-25F-GPS-12V from DC-Digital is a compact flush-mounted GPS atomic clock designed specifically for vehicle applications where accurate and dependable time is essential. Featuring bright 2.3-inch LED digits, this clock is ideal for buses, ambulances, trucks, service vehicles, and other mobile installations requiring a precise time reference powered directly from …

GPS-Atomic Master Clock that can sit in a window seal. Plug and Play, Atomic Timing Solution, GPS Clock, Window Sill Mount, Marine Grade Receiver, School Clock System, Clock Synchronization System, Campus Clock System, Multi Time Zone
Clean Room Clocks
GPS-Wireless and Wired Master Clock for Synchronized System Clocks

Keeping every clock in a facility synchronized no longer requires a complicated network setup, dedicated IT resources, or extensive electrical work. The DC-Digital GPS Atomic Master Clock offers a simple, reliable, and economical solution for distributing accurate time throughout an entire building or campus. Designed for easy installation, this compact …